Table 2 Parameters and RMSE of the FvCB model for the A-Ci response at 10 days after the emergence of cucumber seedlings were measured using steady and unsteady state methods in a portable photosynthesis system, chambers A and B

From: Development of a semi-open chamber system for the gas exchange measurement of whole-canopy under steady and unsteady states in cucumber seedlings

Measurement type

Vcmaxx

Jmax

RMSEy

Portable photosynthesis system

33.9

bz

99.6

d

0.3

e

Chamber A

Standard

30.6

cd

83.5

g

1.1

de

0 to 1000

27.6

e

97.2

de

2.7

bc

0 to 800

32.7

bc

114.9

c

6.9

a

0 to 500

41.9

a

122.5

b

7

a

800 to 400

33.9

b

89

f

1.9

cd

Chamber B

Standard

31.7

bcd

82.5

g

1.6

cde

0 to 1000

23.6

f

74.5

h

3.9

b

0 to 800

29.8

de

100.3

d

4.2

b

0 to 500

42.5

a

134.1

a

7.4

a

800 to 400

33.9

b

94.6

e

2.7

bc

  1. z Identical lowercase letters indicate that means are not significantly different according to Tuckey’s HSD test (p > 0.05). Different lower case letters indicate that means are significantly different according to Tuckey's HSD test (p > 0.05)
  2. y RMSE for each model was calculated through the values measured by the standard A-Ci response and the values estimated by the FvCB model
  3. x Vcmax maximum rate of Rubisco activity-limited carboxylation, Jmax the maximum value of the rate of electron transport under saturated light