Skip to main content

Table 1 Features calculated for each sorted particle using measurements by the large particle flow cytometer

From: A high throughput method for quantifying number and size distribution of Arabidopsis seeds using large particle flow cytometry

Feature

Description

Extinction

Integral optical density of the particle

Size

Calculated from Time-of-flight (TOF) using a calibration curve constructed with standard beads (size = 0.18 TOF + 38.32)

rF510

Fluorescence emission in the waveband 497–523 nm relative to average fluorescence emission across all wavebands

rF543

Fluorescence emission in the waveband 531–555 nm relative to average fluorescence emission across all wavebands

rF615

Fluorescence emission in the waveband 602–628 nm relative to average fluorescence emission across all wavebands

P

Maximum optical density in the optical density profile (Fig. 2)

Px

Location within the optical density profile where the maximum occurs (Fig. 2)

C

Circularity index calculated from the optical density profile (Fig. 2)