Skip to main content

Table 2 Sensitivity scores for each electrical variable in conditions similar to the widely used LCR meters

From: Benchmarking electrical methods for rapid estimation of root biomass

Electrical variable

Frequency (Hz)

Sensitivity score

r 2

Cp

116

0.49

0.542

 

1250

0.46

0.524

 

13,458

0.50

0.605

Cs

116

0.10

0.119

 

1250

0.29

0.331

 

13,458

0.38

0.436

Rp

116

0.40

0.584**

 

1250

0.45

0.635**

 

13,458

0.38

0.599**

Rs

116

0.39

0.563**

 

1250

0.44

0.615**

 

13,458

0.44

0.639**

G

116

0.28

0.317

 

1250

0.35

0.394

 

13,458

0.45

0.502

Z

116

0.39

0.574**

 

1250

0.44

0.628**

 

13,458

0.41

0.622**

X

116

0.18

0.281

 

1250

0.42

0.595**

 

13,458

0.46

0.650**

Θ

116

0.00

0.197

 

1250

0.00

0.214

 

13,458

0.03

0.267

  1. The sensitivity scores, coefficients of determination with root dry mass (r 2), for each electrical variable in LCR meter conditions (test signal frequencies of 116, 1250 and 13,458 Hz, in 2T configuration). The highest sensitivity score is obtained by parallel capacitance (Cp) at 13,458 Hz
  2. *** Linear regression is significant at the 0.01 level
  3. ** Linear regression is significant at the 0.05 level