Skip to main content

Table 2 External calibration curves carried out in headspace and by liquid addition of standards to stir bars

From: A comparison of semi-quantitative methods suitable for establishing volatile profiles

External calibration curve

Standard

Retention time

Calibration curve

r2

Unit

Standards to sampling system (1B)

Ocimene (E)

6.60

6.299·108 ×

0.98

mg

Ocimene (Z)

6.80

1.196·109 ×

0.98

Acetophenone

7.20

5.247·108 ×

0.96

Methyl benzoate

7.77

1.345·109 ×

0.96

Methyl cinnamate

12.61

2.891·109 ×

0.99

Standards to stir bars (2)

Ocimene (E)

6.54

3.424·106 × − 9.325·104

0.99

µg

Ocimene (Z)

6.81

8.318·106 × − 1.397·105

0.99

Acetophenone

7.18

1.052·107 × − 2.693·105

0.99

Methyl benzoate

7.78

1.181·107 × − 1.009·105

0.99

Methyl cinnamate

12.66

1.762·107 × − 5.245·105

1